An International Publisher for Academic and Scientific Journals
Author Login 
Scholars Academic Journal of Pharmacy | Volume-6 | Issue-11
Analytical method validation and quantification of raloxifene hydrochloride and its related substance in API using reverse phase - liquid chromatographic method
Yenisetty Ranganayakulu, Korupolu Raghu Babu, Tentu Nageswara Rao, Avuthu Muralidhar Reddy
Published: Nov. 30, 2017 | 83 115
DOI: 10.21276/sajp.2017.6.11.4
Pages: 468-475
Downloads
Abstract
The present paper describes the reverse phase-high performance liquid chromatographic method and was validated as per ICH guidelines for the determination of related substances in raloxifene hydrochloride. RP-Liquid chromatography technique was performed with pH 3.0 phosphate buffer and acetonitrile as mobile phase at a flow rate of 1.0 mL/minon Waters 2489 UV 2695 pump, Waters 2998 PDA 2695 pump Software Empower 3, with photodiode array detector using Inertsil BDS C8 250 x 4.6 mm, 5µm column with UV detection at 280 nm. The method is specific and % RSD for system precision were 0.18 and 0.35 for raloxifene hydrochloride and Impurity- A respectively. For Method precision, % RSD for Raloxifene hydrochloride was 0.17 %. Linearity were observed for Raloxifene hydrochloride and Impurity- A, in the concentration range of 0.0006 and 0.0045 were linear (R2 = 0.9999 and R2 = 0.9999) Accuracy is calculated as % recovery. % Recovery for accuracy levels at 50, 100 and 150 % L for Raloxifene hydrochloride and Impurity- A were 103.56 ± 0.19, 114.23 ± 0.36, 107.09 ± 0.61 and 103.51 ± 0.30, 1143.41 ± 0.15, 103.62± 0.26, respectively.